ICM Controls ICM175 Bypass Timer Relay, 10-1,000 Seconds Adjustable, Universal 18-240 VAC
- Designed to bypass a low pressure switch or other device during startup
- Ideal for low ambient startups
- Key component for “”winter start”” kits
- Helps to reduce nuisance lockouts
- Universal AC voltage operation
- Knob-adjustable time delays: 10-1,000 seconds
- UL Approval: E53944
Applications
ON delay interval timer, normally closed delay on make.
Designed to bypass a control or device during startup. Typically used to bypass a low pressure switch during compressor heat pump startup or to bypass an oil pressure switch upon startup. Helps to eliminate nuisance lockouts.
Mode of Operation
With power applied to the input, the load energizes immediately and remains energized for the length of the time delay, regardless of the state of the switch being bypassed. At the end of the time delay, the condition of the load is determined by the state of the switch.
SPECIFICATIONS
- Voltage: 18-240 VAC
- 1 amps
- 10 amp inrush
- 40mA holding current
- Frequency: 50/60 Hz
- Knob adjustable time delay: 10-1,000 sec.
- Dimensions: 2.00″ x 2.00″ x 1.25″
REPLACES
- Mars: 32395
- Supco: TD32
Installation Guide
Reviews
There are no reviews yet.