ICM Controls ICM203F Delay on Break Timer with .03-10 Minute Adjustable Time Delay, Universal 18-240 VAC, 6″ Wire Leads
- Compressor lockout/anti-short cycle timer
- Helps to protect compressors from damage caused by rapid short cycling
- Simple, 2-wire hookup
- Adjustable timing
- Universal voltage
- 6-inch wire leads
SPECIFICATIONS
- Voltage: 18-240 VAC
- 1.5 amps
- 15 amp inrush
- Frequency: 50/60 Hz
- Knob-adjustable delays: .03-10 mins. (1.8-600 sec.)
- Voltage drop:
- 3.5 V typical
- 4.5 V maximum @ 1.5 amps
- Holding current minimum: 40 mA
- Dimensions: 2″ x 2″
REPLACES
- Supco: TD73W
- Wagner/DiversiTech: ADB-2
Mode of Operation
With application of power, the load is energized. When the thermostat opens or when there is a loss of power, the load is de-energized and the delay period begins. The compressor will not start again during the delay period. The ICM203 provides true thermostat interruption protection, even in the presence of a trickle current.